SJ100 Inverter Specifications

Getting Star

ted

1–8

Item

400V Class Specifications

SJ100 inverters,
400V models

CE version

004HFE

007HFE

015HFE

022HFE

UL version

004HFU

007HFU

015HFU

022HFU

Applicable motor size *2

kW

0.4

0.75

1.5

2.2

HP

1/2

1

2

3

Rated capacity (460V) kVA

1.1

1.9

2.9

4.2

Rated input voltage

3-phase: 380 to 460V ±10%, 50/60 Hz ±5%

Rated input current (A)

2.0

3.3

5.0

7.0

Rated output voltage *3

3-phase: 380 to 460V (corresponding to input voltage)

Rated output current (A)

1.5

2.5

3.8

5.5

Efficiency at 100% rated output (%)

92.0

93.7

95.7

95.8

Watt loss,
approximate (W)

at 70% output

25

33

48

68

at 100% output

32

44

65

92

Starting torque *6

200% or more

Dynamic braking
approx. %
torque, short
time stop *7

without resistor,
from 50/60 Hz

100%:

≤ 50Hz

50%:

≤ 60Hz

70%:

≤ 50Hz

20%:

≤ 60Hz

with resistor

150%

100%

DC braking

Variable operating frequency, time, and braking force

Weight

kg

1.3

1.7

1.7

1.8

lb

2.87

3.75

3.75

3.97