SJ100 Inverter

Conf

igur

ing

Dr
iv

e P

a

ra

m

e

ters

3–31

“B” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FE

(CE)

–FU

(UL)

–FR

(Jpn)

Units

B_81 [FM] terminal analog

meter adjustment

Adjust 8-bit gain to analog
meter connected to terminal
[FM], range is 0 to 255

80

80

80

ADJ 080

B_82 Start frequency adjust-

ment

Sets the starting frequency for
the inverter output, range is 0.5
to 9.9 Hz

0.5

0.5

0.5

Hz

Fmin 0.5Hz

B_83 Carrier frequency

setting

Sets the PWM carrier (internal
switching frequency), range is
0.5 to 16.0 kHz

5.0

5.0

12.0

kHz

CARRIER 05.0kHz

B_84 Initialization mode

(parameters or trip
history)

Select the type of initialization
to occur, two option codes:
00... Trip history clear
01... Parameter initialization

00

INIT MODE TRP

B_85 Country code for initial-

ization

Select default parameter values
for country on initialization,
four options, option codes:
00... Japan version
01... Europe version
02... US version
03... reserved (do not set)

01

02

00

INIT SEL USA

B_86 Frequency scaling

conversion factor

Specify a constant to scale the
displayed frequency for D_07
monitor, range is 0.1 to 99.9

1.0

1.0

1.0

/Hz01.0 0.00

B_87 STOP key enable

Select whether the STOP key
on the keypad is enabled, two
option codes:
00... enabled
01... disabled

00

00

00

STOP-SW ON

Advertising