Multi-speed and Jog Frequency Setting

The SJ100 inverter has the capability to store and output up to 16 preset frequencies to
the motor (A_20 to A_35). As in traditional motion terminology, we call this multi-speed
profile
capability. These preset frequencies are selected by means of digital inputs to the
inverter. The inverter applies the current acceleration or deceleration setting to change
from the current output frequency to the new one. The first multi-speed setting is dupli-
cated for the second motor settings (the remaining 15 multi-speeds apply only to the first
motor).

The jog speed setting is used whenever the Jog command is active. The jog speed setting
range is arbitrarily limited to 10 Hz, to provide safety during manual operation. The
acceleration to the jog frequency is instantaneous, but you can choose from three modes
for the best method for stopping the jog operation.

“A” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FE

(CE)

–FU

(UL)

–FR

(Jpn)

Units

A_11 O/OI–L input active

range start frequency

The output frequency corre-
sponding to the analog input
range starting point

0

0

0

Hz

IN EXS 000.0Hz

A_12 O/OI–L input active

range end frequency

The output frequency corre-
sponding to the analog input
range ending point

0

0

0

Hz

IN EXE 000.0Hz

A_13 O/OI–L input active

range start voltage

The starting point (offset) for
the active analog input range

0

0

0

%

IN EX%S 000%

A_14 O/OI–L input active

range end voltage

The ending point (offset) for
the active analog input range

100

100

100

%

IN EX%E 100%

A_15 O/OI–L input start

frequency enable

Two options; select codes:
00... Use offset (A_11 value)
01... Use 0 Hz

01

01

01

IN LEVEL 0Hz

A_16 External frequency

filter time constant

Range n = 1 to 8, where n =
number of samples for avg.

8

8

8

Sam-

ples

IN F-SAMP 8