Keys, modes, and parameters – Hitachi SJ100 User Manual

Page 66

Advertising
background image

Using the Front Panel Keypad

In

v

e

rt

er Mounting

and Installation

2–22

Parameter Display - A 4-digit, 7-segment display for parameters and function codes.

Display Units, Hertz/Amperes - One of these LEDs will be ON to indicate the units

associated with the parameter display.

Power LED - This LED is ON when the power input to the inverter is ON.

Function Key - This key is used to navigate through the lists of parameters and

functions for setting and monitoring parameter values.

Up/Down ( ,

) Keys - Use these keys alternately to move up or down the lists of

parameter and functions shown in the display, and increment/decrement values.

Store (

) Key - When the unit is in Program Mode and you have edited a parameter

value, press the Store key to write the new value to the EEPROM.

Keys, Modes, and Parameters

Purpose of the keypad is to provide a way to change modes and parameters. The term
function applies to both monitoring modes and parameters. These are all accessible
through function codes that are primarily 3-character codes. The various functions are
separated into related groups identifiable by the left-most character, as the table shows.

For example, function “A_04” is the base frequency setting for the motor, typically
50 Hz or 60 Hz. To edit the parameter, the inverter must be in Program Mode (PGM
LED will be ON). You use the front panel keys to first select the function code “A_04.”
After displaying the value for “A_04,” use the Up/Down (

or

) keys to edit it.

NOTE: The inverter 7-segment display shows lower case “b” and “d,” meaning the same
as the upper case letters “B” and “D” used in this manual (for uniformity “A to F”).

The inverter automatically switches into Monitor
Mode when you access “D” Group functions. It
switches into Program Mode when you access
any other group, because they all have editable
parameters. Error codes use the “E” Group, and
appear automatically when a fault event occurs.
Refer to

“Monitoring Trip Events, History, &

Conditions” on page 6–5

for error code details.

1

2

STR

Function

Group

Type (Category) of Function

Mode to Access

PGM LED

Indicator

“D”

Monitoring functions

Monitor

“F”

Main profile parameters

Program

“A”

Standard functions

Program

“B”

Fine tuning functions

Program

“C”

Intelligent terminal functions

Program

“H”

Motor constant functions

Program

“E”

Error codes

1

2

“D” Group

MONITOR

PROGRAM

“A” Group
“B” Group
“C” Group
“F” Group
“H” Group

“D” Group

Advertising