Example Wiring Diagram

Oper

ations

and Monitor

ing

4–6

Specifications of Control and Logic Connections

The control logic connectors are located just behind the front panel half-door. The relay
contacts are accessible behind the main door. Connector labeling is shown below.

Specifications for the logic connection terminals are in the following table:

Note 1:

The two terminals [L] are electrically connected together inside the inverter.

Relay

contacts

Logic

inputs

Analog

inputs

Analog

output

Logic

outputs

12 11

1

2

3

4

5

6

L

L

H O OI

FM CM2

P24

AL0

AL2

AL1

Terminal Name

Description

Ratings

[P24]

+24V for logic inputs

24VDC, 30 mA max (do not short to terminal L)

[1], [2], [3], [4], [5],
[6]

Discrete logic inputs

27VDC max. (use P24 or an external supply refer-
enced to terminal L)

[L] (top row) *1

GND for logic inputs

sum of input 1-6 currents (return)

[11], [12]

Discrete logic outputs

50mA maximum ON state current,
27 VDC maximum OFF state voltage

[CM2]

GND for logic outputs

100 mA: sum of 11 and 12 currents (return)

[FM]

PWM (analog/digital) output 0 to 10VDC, 1 mA, PWM and 50% duty digital

[L] (bottom row) *1 GND for analog inputs

sum of OI, O, and H currents (return)

[OI]

Analog input, current

4 to 19.6 mA range, 20 mA nominal

[O]

Analog input, voltage

0 to 9.6 VDC range, 10VDC nominal,
input impedance 10 k

[H]

+10V analog reference

10VDC nominal, 10 mA max

[AL0]

Relay common contact

250 VAC, 2.5A (R load) max.,
250 VAC, 0.2A (I load, P.F.=0.4) max.
100 VAC, 10mA min.
30 VDC, 3.0A (R load) max.
30 VDC, 0.7A (I load, P.F.=0.4) max.
5 VDC, 100mA min.

[AL1]

Relay contact, normally
closed during RUN

[AL2]

Relay contact, normally open
during RUN

Advertising