Hitachi SJ100 User Manual

Page 105

Advertising
background image

SJ100 Inverter

Conf

igur

ing

Dr
iv

e P

a

ra

m

e

ters

3–33

B_90: Dynamic braking usage ratio – This parameter limits the amount of time the
inverter can use the dynamic braking accessory device without entering the Trip Mode.
Please refer to

“Dynamic Braking” on page 5–5

for more information on dynamic

braking accessories.

“B” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FE

(CE)

–FU

(UL)

–FR

(Jpn)

Units

B_88 Restart mode after FRS

Selects how the inverter
resumes operation when the
free-run stop (FRS) is
cancelled, two options:
00... Restart from 0Hz
01... Restart from frequency
detected from real speed of
motor (frequency matching)

00

00

00

RUN FRS ZST

B_89 Data select for digital

operator OPE-J

Select the monitoring data to
send to the optional remote
hand-held digital operator,
seven option codes:
01... Output frequency (D_01)
02... Output current (D_02)
03... Motor direction (D_03)
04... PID PV feedback (D_04)
05... Input states for input
terminals (D_05)
06... Output states for output
terminals (D_06)
07... Scaled output frequency
(D_07)

01

01

01

PANEL d01

B_90 Dynamic braking usage

ratio

Selects the rate of use (in %) of
the regenerative braking
resistor per 100 sec. intervals,
range is 0.0 to 100.0%
0% . Dynamic braking disabled
>0% Enabled, per value

0.0

0.0

0.0

%

BRD-%ED 000.0%

B_91 Stop mode selection

Selects how the inverter stops
the motor, two option codes:
00... DEC (decelerate and stop)
01... FRS (free run to stop)

00

00

00

RUN STP DEC

B_92 Cooling fan control

Selects when the fan is ON per
inverter operation, two options:
00... Fan is always ON
01... Fan is ON during run,
OFF during stop

00

00

00

INIT FAN-CTL OFF