“H” Group: Motor Constants Functions

Introduction

The “H” Group parameters configure the
inverter for the motor characteristics. You
must manually set H_03 and H_04 values to
match the motor. The remaining parameters
are related to sensorless vector control (SLV),
and are in use only when function A_44 is set
for SLV as shown in the diagram. The proce-
dure in

“Auto-tuning for Sensorless Vector

Control” on page 4–35

automatically sets all

the parameters related to SLV. If you config-
ure the inverter to use SLV, we highly recommend letting the auto-tuning procedure
derive the values for you. If you want to reset the parameters to the factory default
settings, use the procedure in

“Restoring Factory Default Settings” on page 6–8

.

NOTE: The auto-tuning procedure and related warning messages are in

“Auto-tuning

for Sensorless Vector Control” on page 4–35

. Please read these before trying to auto-

tune the motor parameters.

Output

Inverter Torque Control Algorithms

A 44

V/f control,

constant torque

V/f control,

variable torque

Sensorless vector

(SLV) control

00

01

02

“H” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FE

(CE)

–FU

(UL)

–FR

(Jpn)

Units

H_01 Auto-tuning Setting

Three states for auto-tuning
function, option codes:
00... Auto-tuning OFF
01... Auto-tune (rotate motor)
02... Auto-tune (measure motor
resistance and inductance,
without rotating)

00

00

00

AUX AUTO NOR

H_02 Motor data selection

Two selections, option codes:
00... Use standard motor data
01... Use auto-tuning data

00

00

00

AUX DATA NOR

H202 Motor data selection,

2nd motor

Two selections, option codes:
00... Use standard motor data
01... Use auto-tuning data

00

00

00

2AUXDATA NOR

H_03 Motor capacity

Nine selections:
0.2 / 0.4 / 0.75 / 1.5 / 2.2 / 3.7
5.5 / 7.5 / 11

Specified by the
capacity of each

inverter model

kW

AUX K 0.4 kW

H203 Motor capacity, 2nd

setting

Nine selections:
0.2 / 0.4 / 0.75 / 1.5 / 2.2 / 3.7
5.5 / 7.5 / 11

Specified by the
capacity of each

inverter model

2AUXK 0.4 kW

H_04 Motor poles setting

Four selections:
2 / 4 / 6 / 8

4

4

4

poles

AUX P 4p