Second Acceleration and Deceleration Functions

The SJ100 inverter features two-stage acceleration and deceleration ramps. This gives
flexibility in the profile shape. You can specify the frequency transition point, the point
at which the standard acceleration (F_02) or deceleration (F_03) changes to the second
acceleration (A_92) or deceleration (A_93). These profile options are also available for
the second motor settings. Select a transition frequency method via A_94 as depicted
below. Be careful not to confuse the second acceleration/deceleration settings with
settings for the second motor!

Accel 1

Accel 2

2CH

input

Frequency

transition point

A 95

A_94 = 00

A_94 = 01

Output

frequency

Output

frequency

t

t

Accel 1

Accel 2

t

Transition via 2CH input

Transition via freq. level

0

0

1
0

“A” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FE

(CE)

–FU

(UL)

–FR

(Jpn)

Units

A_92 Acceleration (2) time

setting

Duration of 2nd segment of
acceleration, range is:
0.1 to 3000 sec.

15.0

15.0

15.0

sec.

ACC 2 0015.0s

A292 Acceleration (2) time

setting, (2nd motor)

Duration of 2nd segment of
acceleration, 2nd motor,
range is: 0.1 to 3000 sec.

15.0

15.0

15.0

sec.

2ACC2 0015.0s

A_93 Deceleration (2) time

setting

Duration of 2nd segment of
deceleration, range is:
0.1 to 3000 sec.

15.0

15.0

15.0

sec.

DEC 2 0015.0s

A293 Deceleration (2) time

setting, (2nd motor)

Duration of 2nd segment of
deceleration, 2nd motor,
range is: 0.1 to 3000 sec.

15.0

15.0

15.0

sec.

2DEC2 0015.0s

A_94 Select method to switch

to Acc2/Dec2 profile

Two options for switching
from 1st to 2nd accel/decel:
00... 2CH input from terminal
01... transition frequency

00

00

00

ACC CHG TM

A294 Select method to switch

to Acc2/Dec2 profile,
2nd motor

Two options for switching
from 1st to 2nd accel/decel:
00... 2CH input from terminal
01... transition frequency
(2nd motor)

00

00

00

2ACCCHG TM