Motor control accesso ri es – Hitachi SJ100 User Manual

Page 168

Advertising
background image

Dynamic Braking

Motor Control

Accesso

ri

es

5–10

Use one BRD–E2 braking unit for the braking torque listed in the following table.

Note the column meanings in the tables:

• Column “A” = Average braking torque from 60 Hz to 3 Hz.

• Column “B” = Average braking torque from 120 Hz to 3 Hz.

Connect a second braking unit in parallel for additional braking torque listed in the
following table.

SJ100 Inverter 200V Models

Braking Torque with BRD–E2 Braking Unit

Model Number

HP

Braking torque

without

braking unit

Using built-in

resistor only

External resistor added

HRB1

HRB2

HRB3

A

B

A

B

A

B

A

B

002NFE/NFU

1/4

50%

150%

120%

004NFE/NFU

1/2

50%

150%

120%

005NFE

3/4

50%

100%

80%

150%

120%

007NFE/NFU

1

50%

100%

80%

150%

120%

011NFE

1.5

50%

60%

60%

100%

80%

015NFE/NFU

2

50%

50%

50%

100%

80%

022NFE/NFU

3

20%

50%

50%

100%

80%

037LFU

5

20%

40%

40%

60%

60%

100%

80%

150%

120%

055LFU

7.5

20%

30%

30%

50%

50%

80%

60%

100%

80%

075LFU

10

20%

20%

20%

40%

40%

60%

60%

80%

80%

SJ100 Inverter 200V Models

Braking Torque with TWO (2) BRD–E2 Braking Units

Model Number

HP

Braking torque

without

braking unit

Using built-in

resistor only

External resistor added

HRB1

HRB2

HRB3

A

B

A

B

A

B

A

B

002NFE/NFU

1/4

50%

150%

150%

004NFE/NFU

1/2

50%

150%

150%

005NFE

3/4

50%

150%

150%

007NFE/NFU

1

50%

150%

120%

011NFE

1.5

50%

100%

80%

015NFE/NFU

2

50%

70%

70%

150%

120%

022NFE/NFU

3

20%

70%

70%

150%

120%

037LFU

5

20%

50%

50%

110%

90%

055LFU

7.5

20%

30%

30%

80%

80%

90%

90%

100%

80%

075LFU

10

20%

30%

30%

60%

60%

80%

80%

100%

80%