Getting star ted – Hitachi SJ100 User Manual

Page 29

Advertising
background image

SJ100 Inverter Specifications

Getting Star

ted

1–10

Input
signal

Freq.
setting

Operator panel

Up and Down keys / Value settings

Potentiometer

Analog setting

External signal
*8

0 to 10 VDC (input impedance 10k Ohms), 4 to 20 mA (input
impedance 250 Ohms), Potentiometer (1k to 2k Ohms, 2W)

FWD/
REV
Run

Operator panel

Run/Stop (Forward/Reverse run change by command)

External signal

Forward run/stop, Reverse run/stop

Intelligent input
terminal

FW (forward run command), RV (reverse run command), CF1~CF4
(multi-stage speed setting), JG (jog command), 2CH (2-stage accel./
decel. command), FRS (free run stop command), EXT (external
trip), USP (startup function), SFT (soft lock), AT (analog current
input select signal), RS (reset), PTC (thermal protection), DB (exter-
nal DC braking command), SET (2nd setting selection), UP (remote
control, accel.), DWN (remote control, decel.)

Output
signal

Intelligent output
terminal

RUN (run status signal), FA1,2 (frequency arrival signal), OL
(overload advance notice signal), OD (PID error deviation signal),
AL (alarm signal)

Frequency monitor

PWM output; Select analog output frequency monitor, analog output
current monitor or digital output frequency monitor

Alarm output contact

ON for inverter alarm (1C contacts, both normally open or closed
avail.)

Other functions

AVR function, curved accel/decel profile, upper and lower limiters,
16-stage speed profile, fine adjustment of start frequency, carrier
frequency change (0.5 to 16 kHz) frequency jump, gain and bias
setting, process jogging, electronic thermal level adjustment, retry
function, trip history monitor, 2nd setting selection, auto tuning, fan
ON/OFF selection

Protective function

Over-current, over-voltage, under-voltage, overload, extreme high/
low temperature, CPU error, memory error, ground fault detection at
startup, internal communication error, electronic thermal, CT error

Operat-
ing
Environ
ment

Temperature

Operating (ambient): -10 to 50

°C (*9) / Storage: -25 to 70°C (*10)

Humidity

20 to 90% humidity (non-condensing)

Vibration *11

5.9 m/s

2

(0.6G), 10 to 55 Hz

Location

Altitude 1,000 m or less, indoors (no corrosive gasses or dust)

Coating color

Munsell 8.5YR6.2/0/2, cooling fins in base color of aluminum

Options

Remote operator unit, copy unit, cables for the units, braking unit,
braking resistor, AC reactor, DC reactor, noise filter, DIN rail
mounting

Item

General Specifications

Advertising