Hitachi SJ100 User Manual

Page 114

Advertising
background image

“C” Group: Intelligent Terminal Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–42

NOTE: Settings C_81 and C_82 are factory-calibrated for each inverter. Do not change
these settings unless absolutely necessary. Note that if you restore factory defaults for all
parameters, these settings will not change.

C_43 Arrival frequency

setting for deceleration

Sets the frequency arrival
setting threshold for the output
frequency during deceleration

0.0

0.0

0.0

Hz

ARV DEC 000.0Hz

C_44 PID deviation level

setting

Sets the allowable PID loop
error magnitude (absolute
value), SP - PV, range is 0.0 to
100%, resolution is 0.1%

3.0

3.0

3.0

%

OV PID 003.0%

C_81 O input span calibration Scale factor between the

external frequency command
on terminals L – O (voltage
input) and the frequency output

Factory-calibrated

ADJ-O 082

C_82 OI input span calibra-

tion

Scale factor between the
external frequency command
on terminals L – OI (current
input) and the frequency output

Factory-calibrated

ADJ-OI 066

C_91 Debug mode enable

(Reserved) DO NOT EDIT

00

00

00

INIT DEBG OFF

C_92 Core monitor address

(Reserved) DO NOT EDIT

0000

0000

0000

(not displayed)

C_93 Core monitor date

(Reserved) DO NOT EDIT

(not displayed)

C_94 Core set address

(Reserved) DO NOT EDIT

D_01

D_01

D_01

(not displayed)

C_95 Core set date

(Reserved) DO NOT EDIT

00

00

00

(not displayed)

“C” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FE

(CE)

–FU

(UL)

–FR

(Jpn)

Units