“H” Group: Motor Constants Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–44

H204 Motor poles setting, 2nd

motor

Four selections:
2 / 4 / 6 / 8

✘

4

4

4

poles

2AUXP 4p

H_05 Motor speed constant

Motor proportional gain
constant (factory set),
range is 0 to 99

✘

20

20

20

—

AUX KP 20

H205 Motor speed constant,

2nd motor

Motor proportional gain
constant (factory set)
range is 0 to 99

✘

20

20

20

—

2AUXKP 20

H_06 Motor stabilization

constant

Motor constant (factory set),
range is 0 to 255

✘

100

100

100

—

AUX KCD 100

H206 Motor stabilization

constant, 2nd motor

Motor constant (factory set),
range is 0 to 255

✘

100

100

100

—

2AUXKCD 100

H_20 Motor constant R1

Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53

✘

Factory set according

to inverter model

Ohms

AUX R1 05.700*

H220 Motor constant R1, 2nd

motor

Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53

✘

Factory set according

to inverter model

Ohms

2AUXR1 05.700*

H_21 Motor constant R2

Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53

✘

Factory set according

to inverter model

Ohms

AUX R2 02.773

H221 Motor constant R2, 2nd

motor

Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53

✘

Factory set according

to inverter model

Ohms

2AUXR2 02.773

H_22 Motor constant L

Range is 0.00 - 655.3 mH,
0.00 to 99.99
100.0 - 655.3

✘

Factory set according

to inverter model

mH

AUX L 045.70mH

H222 Motor constant L,

2nd motor

Range is 0.00 - 655.3 mH,
0.00 to 99.99
100.0 - 655.3

✘

Factory set according

to inverter model

mH

2AUXL 045.70mH

H_23 Motor constant I

o

Range is 0.00 to 655.3 Amps,
0.00 to 99.99
100.0 - 655.3

✘

Factory set according

to inverter model

Arms

AUX I0 001.50A

H223 Motor constant I

o

, 2nd

motor

Range is 0.00 to 655.3 Amps,
0.00 to 99.99
100.0 - 655.3

✘

Factory set according

to inverter model

Arms

2AUXI0 001.50A