Using the front panel keypad, Front panel introduction, Parameter editing controls – Hitachi SJ100 User Manual

Page 65: Using the front panel keypad 2–21

Advertising
background image

SJ100 Inverter

In

v

e

rt

er Mounting

and Installation

2–21

Using the Front Panel Keypad

Front Panel Introduction

Please take a moment to familiarize yourself with the keypad layout shown in the figure
below. These are the visible controls and indicators when the front panel door is closed.

The display is used in programming the inverter’s parameters, as well as monitoring
specific parameter values during operation. Many functions are applicable only during
the initial installation, while others are more useful for maintenance or monitoring.

Parameter Editing Controls

Now, open the front panel (half-door) for
second-level access to reveal additional operator
keys for parameter editing as shown to the right.
In normal operation after installation, parameter
editing is unnecessary, so these controls are
hidden from view. The front panel controls and
indicators are described as follows:

Run/Stop LED - ON when the inverter output

is ON and the motor is developing torque
(Run Mode), and OFF when the inverter
output is OFF (Stop Mode).

Program/Monitor LED - This LED is ON

when the inverter is ready for parameter editing (Program Mode). It is OFF when the
parameter display is monitoring data (Monitor Mode).

Run Key Enable LED - is ON when the inverter is ready to respond to the Run key,

OFF when the Run key is disabled.

Run Key - Press this key to run the motor (the Run Enable LED must be ON first).

Parameter F_04, Keypad Run Key Routing, determines whether the Run key generates
a Run FWD or Run REV command.

Stop/Reset Key - Press this key to stop the motor when it is running (uses the

programmed deceleration rate). This key will also reset an alarm that has tripped.

Potentiometer - Allows an operator to directly set the motor speed when the potenti-

ometer is enabled for output frequency control.

Potentiometer Enable LED - ON when the potentiometer is enabled for value entry.

Hz

POWER

A

RUN

PRG

RUN

STOP

RESET

MIN

MAX

HITACHI

5 0.0

Parameter Display

Run/Stop LED

Program/Monitor LED

Run Key Enable LED

Run Key

Stop/Reset Key

Power LED

Display Units
Hertz / Amperes LEDs

Potentiometer Enable LED

Potentiometer

Hz

POWER

A

RUN

PRG

RUN

STOP

RESET

MIN

MAX

HITACHI

FUNC.

STR

1

2

Function

key

Up/Down

keys

Store

key

5 0.0