SJ100 Dynamic Braking Selection Tables

The SJ100 series inverter models have internal braking units. Additional stopping torque
is available by adding external resistors. The required braking torque depends on your
particular application. Other tables in this section will help you choose the proper
resistor.

200V Class

Without

External

Resistor

Using Optional

External

Resistor

Performance at Minimum

Resistance

Min.

Resistance

at 100%

Braking

Duty Cycle

(Ohms)

SJ100

Model Number

HP

Braking

Unit

Braking

Torque

(%)

Resistance

(Ohms)

Braking

Torque

Min.

Resistance

(Ohms)

Braking

Torque

Max.

Braking

Duty

Cycle

(%)

002NFE/NFU

1/4

Built-in

50

180

150

100

200

10

150

004NFE/NFU

1/2

Built-in

50

180

150

100

200

10

150

005NFE

3/4

Built-in

50

180

150

100

200

10

150

007NFE/NFU

1

Built-in

50

100

150

35

200

10

150

011NFE

1.5

Built-in

50

50

150

35

200

10

150

015NFE/NFU

2

Built-in

50

50

150

35

200

10

100

022NFE/NFU

3

Built-in

20

50

100

35

150

10

100

037LFU

5

Built-in

20

35

100

35

100

10

100

055LFU

7.5

Built-in

20

17

80

17

80

10

50

075LFU

10

Built-in

20

17

80

17

80

10

50

400V Class

Without

External

Resistor

Using Optional

External

Resistor

Performance at Minimum

Resistance

Min.

Resistance

at 100%

Braking

Duty Cycle

(Ohms)

SJ100

Model Number

HP

Braking

Unit

Braking

Torque

(%)

Resistance

(Ohms)

Braking

Torque

Min.

Resistance

(Ohms)

Braking

Torque

Max.

Braking

Duty

Cycle

(%)

004HFE/HFU

1/2

Built-in

50

180

150

180

150

10

500

007HFE/HFU

1

Built-in

50

180

150

180

150

10

300

015HFE/HFU

2

Built-in

50

180

150

180

150

10

300

022HFE/HFU

3

Built-in

20

100

100

100

100

10

300

030HFE

4

Built-in

20

100

100

100

100

10

200

040HFE/HFU

5

Built-in

20

100

100

100

100

10

200

055HFE/HFU

7.5

Built-in

20

70

80

70

80

10

200

075HFE/HFU

10

Built-in

20

70

80

70

80

10

150

Advertising