Preset speed mode control, Preset speed #13, Preset speed #14 – Toshiba W7 User Manual

Page 109: Preset speed #15, Proportional (p) gain

Advertising
background image

W7 ASD Installation and Operation Manual

103

Preset Speed #13

Program

Preset Speeds

13

This parameter assigns an output frequency to binary number 1101 and is
identified as Preset Speed #13. The binary number is applied to S1S4 of the
Control Terminal Strip to output the Preset Speed (see

Preset Speed #1

for

further information on this parameter).

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit

Maximum — Upper Limit

Units — Hz

Preset Speed #14

Program

Preset Speeds

14

This parameter assigns an output frequency to binary number 1110 and is
identified as Preset Speed #14. The binary number is applied to S1S4 of the
Control Terminal Strip to output the Preset Speed (see

Preset Speed #1

for

further information on this parameter).

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit

Maximum — Upper Limit

Units — Hz

Preset Speed #15

Program

Preset Speeds

15

This parameter assigns an output frequency to binary number 1111 and is
identified as Preset Speed #15. The binary number is applied to S1S4 of the
Control Terminal Strip to output the Preset Speed (see

Preset Speed #1

for

further information on this parameter).

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit

Maximum — Upper Limit

Units — Hz

Preset Speed Mode Control

Program

Preset Speeds

Mode

Enables/Disables the use of the Preset Speed Mode control for Preset Speeds
115.

The Preset Speed Mode control setting determines if the Speed setting only is
used (disabled) or if the user-set combinations of the Torque, Speed, Accel/
Decel
, and Direction settings will be used (enabled) while running Preset
Speeds 1
15.

Parameter Type — Selection List

Factory Default — Disabled

Changeable During Run — No

Proportional (P) Gain

Program

Feedback Settings

Proportional Gain

This parameter determines the degree that the Proportional function affects the
output signal when using PID feedback to control the ASD output. The larger
the value entered here, the quicker the ASD responds to changes in feedback.

Parameter Type — Numerical

Factory Default — 0.10

Changeable During Run — Yes

Minimum — 0.01

Maximum — 100.0

Preset Speed #13

Proportional (P) Gain

Advertising