63

Communications Reference Setpoint #1

Program

Communications Settings

Communication Reference

Setpoint #1

When enabled via the Communications Reference Select parameter, this
parameter is used to allow the user to set the gain and bias of the speed control
input to the ASD when the speed control signal is received via the source
selected at the Communications Reference Select parameter.

Gain and Bias Settings

When operating in the Speed Control mode and using one of the control
sources from the Communications Reference Select parameter, the settings
that determine the gain and bias properties of the input signal are:

Communications Speed #1

(Hz)

,

the communications input signal value that represents Communications
Speed #1

(Hz)

,

Communications Speed #2

(Hz)

, and

the communications input signal value that represents Communications
Speed #2

(Hz)

.

Once set, as the input signal value changes, the output frequency of the ASD
will vary in accordance with the above settings.

This parameter sets the Communications Reference input value that represents
Communications Speed #1. This value is entered as 0 to 100% of the
Communications Reference input value range.

Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 100.0

Units — %

Frequency Settings

Communications Reference Setpoint #2

Program

Communications Settings

Comm Reference Setpoint #2

This parameter is used to set the gain and bias of the Communications
Reference
speed control input.

See

Communications Reference Setpoint #1

for further information on this

setting.

This parameter sets the Communications Reference input value that represents
Communications Speed #2 (Hz). This value is entered as 0 to 100% of the
Communications Reference input value range.

Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.

Parameter Type — Numerical

Factory Default — 100.0

Changeable During Run — Yes

Minimum — 0.00

Maximum — 100.0

Units — %

Communications Reference Selection

Program

Communications Settings

Communications Reference

Selection

This parameter Enable/Disables speed control via communications. Selecting a
signal source enables this function. Selecting Disable disables this function.

Settings:

Communications Card
RS232/RS485
LCD Keypad
Disabled

Parameter Type — Selection List

Factory Default — Disabled

Changeable During Run — Yes

Communications Reference Setpoint #1

Communications Reference Selection