F terminal on pg. 75, Frequency mode #1, F terminal – Toshiba W7 User Manual

Page 81: Frequency mode (#2)

Advertising
background image

W7 ASD Installation and Operation Manual

75

Frequency Mode #1

Program

Utilities

Command and Frequency Settings

Frequency

Mode #1 Select

The Frequency Mode (#1) setting establishes the source of the frequency-
control input for the ASD.

Settings:

Use VI/II
Use RR
Use RX
Use Option Card RX2
Use LED Keypad Option
Use Binary/BCD Input
Use Common Serial (TTL)
Use RS232/RS485
Use Communication Card
Use Motorized Pot. Simulation
Use Pulse Input Option

Parameter Type — Selection List

Factory Default — Use RR

Changeable During Run — No

Frequency Mode (#2)

Program

Frequency Settings

Reference Priority

Frequency

Mode #2

This parameter selects the source of the frequency command signal to be used
as Frequency Mode #2 in the event that Frequency Mode #1 is disabled or if
Frequency Mode #2 is set up as the primary control parameter.

See the

Reference Priority Selection

parameter for additional information on

this setting.

The Frequency Mode setting establishes the source of the frequency-control
input for the ASD.

Settings:

Use VI/II
Use RR
Use RX
Use Option Card RX2
Use LED Keypad Option
Use Binary/BCD Input
Use Common Serial (TTL)
Use RS232/RS485
Use Communication Card
Use Motorized Pot. Simulation
Use Pulse Input Option

Parameter Type — Selection List

Factory Default — Use RR

Changeable During Run — No

F Terminal

Program

Terminal Settings

Input Terminals

F

This parameter selects the functionality of the F discrete input terminal.

In addition, the input terminal must be specified as Normally Open or
Normally Closed.

This parameter sets the programmable F terminal to 1 of the 69 possible
functions that are listed in

Table 6 on page 138

.

Parameter Type — Selection List

Factory Default — Forward

Changeable During Run — No

Frequency Mode #1

F Terminal

Advertising