W7 ASD Installation and Operation Manual

77

Input Terminal Priority

Program

Terminal Settings

Input Terminals

Other

Input

Terminal Priority Selection

This parameter is used to allow the Jog or the DC Injection Braking input
signals to control the ASD when received via the Control Terminal Strip even
though the system is in the Local mode.

With this parameter enabled, a Jog command or a DC Injection Braking
command received from the Control Terminal Strip will receive priority over
commands from the keypad.

See

Jog Run Frequency

for further information on using the Jog function.

See

DC Injection Braking Current

for further information on this parameter.

Settings:

Enabled
Disabled

Parameter Type — Selection List

Factory Default — Disabled

Changeable During Run — No

Inrush Current Suppression Time (MS Relay Delay)

Program

Protection Settings

Inrush Time

The startup inrush current may be suppressed for up to 2.5 seconds. This
parameter determines the length of the inrush current suppression.

Parameter Type — Numerical

Factory Default — 0.30

Changeable During Run — No

Minimum — 0.30

Maximum — 2.50

Units — Seconds

Integral (I) Gain

Program

Feedback Settings

Integral Gain

This parameter determines the degree that the Integral function affects the
output signal when using PID feedback to control the ASD output. The smaller
the value here, the more pronounced the effect of the integral function on the
output signal.

Parameter Type — Numerical

Factory Default — 0.10

Changeable During Run — Yes

Minimum — 0.01

Maximum — 100.0

Interlock with ST

Program

Protection Settings

Interlock with ST

The MS1 AUX relay circuit is normally open and is in series with the ST-to-
CC connection.

After normal system power is available the MS1 AUX relay circuit closes and
completes the ST-to-CC connection.

Settings:

Disabled
Enabled

Parameter Type — Selection List

Factory Default — Disabled

Changeable During Run — Yes

Input Terminal Priority

Interlock with ST

Advertising