Above the ceiling (plenum) installations – Brocade Mobility 7131N-FGR Access Point Product Reference Guide (Supporting software release 4.0.0.0-35GRN and later) User Manual
Page 43
Brocade Mobility 7131N-FGR Product Reference Guide
31
53-1001947-01
Mounting a Brocade Mobility 7131N-FGR Access Point
2
CAUTION
Ensure the safety wire and cabling used in the T-Bar installation is securely fastened to the
building structure in order to provide a safe operating environment.
11. Rotate the access point chassis 45 degrees counter-clockwise. The clips click as they fasten to
the T-bar.
12. The access point is ready to configure. For information on an access point default
configuration, see
on page 39. For specific details on access point system
configurations, see
Above the ceiling (plenum) installations
An above the ceiling installation requires placing the access point above a suspended ceiling and
installing the provided light pipe under the ceiling tile for viewing the rear panel status LEDs of the
unit. An above the ceiling installation enables installations compliant with drop ceilings, suspended
ceilings and industry standard tiles from .625 to .75 inches thick.
NOTE
The Brocade Mobility 7131N-FGR Access Point is Plenum rated to UL2043 and NEC1999 to support
above the ceiling installations.
CAUTION
Brocade does not recommend mounting the access point directly to any suspended ceiling tile
with a thickness less than 12.7mm (0.5in.) or a suspended ceiling tile with an unsupported span
greater than 660mm (26in.). Brocade strongly recommends fitting the access point with a safety