3 ip irdp holdtime, 4 ip irdp maxadvertinterval, 5 ip irdp minadvertinterval – Kontron AT890X Full-Size CLI User Manual

Page 127: Ip irdp holdtime - 15, Ip irdp maxadvertinterval - 15, Ip irdp minadvertinterval - 15

Advertising
background image

AT8901/2/3

Routing Commands

Page 3 - 15

AT8901/2/3 CLI Reference Manual

Format

no ip irdp address

Mode

Interface Config

3.3.3

ip irdp holdtime

This command configures the value, in seconds, of the holdtime field of the router
advertisement sent from this interface. The holdtime range is the value of

<maxadvertinterval>

to 9000 seconds.

Default

3 * maxinterval

Format

ip irdp holdtime <maxadvertinterval-9000>

Mode

Interface Config

3.3.3.1

no ip irdp holdtime

This command configures the default value, in seconds, of the holdtime field of the
router advertisement sent from this interface.

Format

no ip irdp holdtime

Mode

Interface Config

3.3.4

ip irdp maxadvertinterval

This command configures the maximum time, in seconds, allowed between sending
router advertisements from the interface. The range for maxadvertinterval is 4 to 1800
seconds.

Default

600

Format

ip irdp maxadvertinterval <4-1800>

Mode

Interface Config

3.3.4.1

no ip irdp maxadvertinterval

This command configures the default maximum time, in seconds.

Format

no ip irdp maxadvertinterval

Mode

Interface Config

3.3.5

ip irdp minadvertinterval

This command configures the minimum time, in seconds, allowed between sending
router advertisements from the interface. The range for minadvertinterval is three to the
value of maxadvertinterval.

Default

0.75 * maxadvertinterval

Format

ip irdp minadvertinterval <3-maxadvertinterval>

Mode

Interface Config

3.3.5.1

no ip irdp minadvertinterval

This command sets the default minimum time to the default.

Advertising