Series 3

Operations Manual

21

4.4.6

Level 1 Operator Parameters

A minimal list of parameters are available in operator Level
1 which is designed for day to day operation. Access to
these parameters is not protected by a pass code.

Press

to step through the list of parameters.

The

mnemonic of the parameter is shown in the lower display.
After five seconds a scrolling text description of the
parameter appears.

The value of the parameter is shown in the upper display.
Press

or

to adjust this value. If no key is pressed

for 30 seconds the controller returns to the HOME display

The parameters that appear depend upon the functions
configured. They are:

Parameter

Mnemonic

Scrolling Display

and Description

Alterability

WRK.OP

WORKING OUTPUT
The active output
value

Read only.
Appears when the controller
is in AUTO or OFF mode.

WKG.SP

WORKING
SETPOINT
The active setpoint
value.

Read only.
Only shown when the
controller is in MAN or OFF
mode.

SP1

SETPOINT 1

Alterable

SP2

SETPOINT 2

Alterable

T.REMN

TIME REMAINING
Time to end of set
period

Read only
0:00 to 99.59 hh:mm or
mm:ss

A1.xxx

ALARM 1 SETPOINT Read only.

Only shown if the alarm is
configured.
xxx = alarm type as follows:
HI = High alarm
LO = Low alarm
d.HI = Deviation high
d.LO = Deviation low
d.HI = Deviation high
rrc = Rising rate of change

(units/minute)

Frc = Falling rate of change

(units/minute)

A2.xxx

ALARM 2 SETPOINT

A3.xxx

ALARM 3 SETPOINT

A4.xxx

ALARM 3 SETPOINT

LD.AMP

LOAD CURRENT

Read only. Only shown if CT
is configured

5. Operator Level 2

Level 2 provides access to additional parameters. Access to
these is protected by a security code.

5.1

To Enter Level 2

1. From any display press and hold

.

2. After a few seconds the display will

show

3. Release

.

(If no button is pressed for about 45 seconds the display
returns to the HOME display)

4. Press

or

to

choose Lev 2 (Level 2)

5. After 2 seconds the
display will show

6. Press

or

to enter the

pass code. Default = ‘2’

If an incorrect code is entered the controller reverts to
Level 1.

5.2

To Return to Level 1

1. Press and hold

2. Press

to select LEv 1

The controller will return to the level 1 HOME display.
Note: A security code is not required when going from a
higher level to a lower level.

5.3

Level 2 Parameters

Press

to step through the list of parameters.

The

mnemonic of the parameter is shown in the lower display.
After five seconds a scrolling text description of the
parameter appears.

The value of the parameter is shown in the upper display.
Press

or

to adjust this value. If no key is pressed

for 30 seconds the controller returns to the HOME display
Backscroll is achieved when you are in this list by pressing

while holding down

.

The following table shows a list of parameters available in
Level 2.