Operations Manual

Series 3

42

9.2

Current Transformer Input Parameters (Current Transformer is not available)

This is not available on Series 3 controllers.
Measures, via an external current transformer, the current flowing through the electrical load when the heat output is ‘on’ (load
current) and also when it is ‘off’ (leakage current).

Alarm

If the load current is lower than a threshold limit or the leakage current is higher than a threshold limit,
then an alarm triggers. The hysteresis to exit from either of these alarm conditions is fixed at 2% of the
current transformer span.

Full scale value

Selectable from 10 to 1000A

CURRENT TRANSFORMER LIST ‘C T - i N P ’

Name

Scrolling Display

Parameter Description

Value

Default

Access Level

Ct.Id

MODULE TYPE

CT module identity

Ct.In

CT input circuit fitted

Conf read only

CT.SRC

CT SOURCE

Selects the output controlling the
current measured by the CT input.
The source can only be selected if
the output has been configured for
Heat or Cool

none

None

IO-1

Input/output 1

OP-2

Output 2

aa

AA Relay

CT.RNG

CT RANGE

Sets the CT inputs range

0 to CT full scale value (1000)

Conf

CT.LAT

CT ALARM
LATCH TYPE

To configure the latch mode of the
CT input alarm.
A description of alarm latching is
given in the alarm section

nonE

No latching

no

Conf if CT alarm
enabled

Auto

Latched with automatic
reset

man

Latched with manual reset

Ld.alm

LOAD CURRENT
THRESHOLD

Load open circuit alarm threshold –
low alarm

Off

to CT full scale value (settable to

3000)

Read only

LK.ALM

LEAK CURRENT
THRESHOLD

Leakage current in the off state
alarm threshold – high alarm

Off

to CT full scale value (settable to

3000)

Read only

Hc.alm

OVER
CURRENT
THRESHOLD

Overcurrent threshold – high alarm

Off

to CT full scale value (settable to

3000)

LD.AMP

LOAD CURRENT

Measured load current

L3 if CT input
enabled

LK.AMP

LEAK CURRENT

CT input leakage current

L3 if CT input
enabled

CT.MTR

CT METER RANGE

To set the range of the meter.

0 to 1000

L3