Resolving the DRAM Memory Error

Symptom: An error has occurred in the removable memory Module (SIMM). (Note: The
LCD will state the following: Main Memory Error.)

Step Procedure

1

Reboot the Printer.

2

If the problem persists, remove the rear cover and ensure that the SIMM
(080229) is seated properly.

3

If the memory Module is not seated properly, lock the SIMM into place.

4

If the installation appears correct and the error persists, the SIMM (080229)
on the Main Print Board will need to be replaced.

Resolving the RAM Memory Error

Symptom: An error has occurred in the permanent circuit memory.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, replace the Main Print Board.

3

As an alternative to replacing the Main Print Board, the chip U22 may be
replaced. (Note: Fargo recommends that only a qualified electronics
technician perform this procedure.)