Resolving the fpga error, Sensor testing, Resolving the fpga error -3 – FARGO electronic HDP600-LC CR100 User Manual

Page 357: Sensor testing -3

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

HDP600 High Definition Card Printer/Encoder User Guide (Rev. 2.5)

10-3

Resolving the FPGA Error

Symptom: An unexpected hardware error has occurred.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced.

3

As an alternative to replacing the Main Print Board, the chip U34 may be
replaced. (Note: Fargo recommends that only a qualified electronics
technician perform this procedure.)

Sensor Testing

Step Procedure

1

Check the voltage to determine if a Sensor is working.

2

a. Test the voltage of each Sensor using ground (GRD = Chassis) to the

correct pin on each connector. See Sensor Location and Voltages
table below).

b. Block a slot Sensor with a card.

c. Cover a reflective Sensor with a card.

3

a. Troubleshoot the Ribbon Sensor by using the RibbonTraq marks on the

Ribbon and Film to cover the Ribbon and Film Sensors. (Note: The
numbers indicate the location on J9, as shown in the Sensor Location
and Voltages
table below).

b. Open the upper Module to find the Ribbon Sensor orientation. (Note:

The numbers indicate the location on J9, as shown in the Sensor
Location and Voltages
table below.)