Sony OXF-R3 User Manual

Page 227

Advertising
background image

Chapter 6

Technical Descriptions

6-65

Chapter 6 Technical Descriptions

{PRINT} {TITLE} {ENTER}
Prints details of the current Title.

Note:

“Print” output commands require the system to be configured with a Postscript
compatible printer.

Command Key Functions

{GLOBAL DROP-IN} Key
Causes all controls in automation ‘ready’ status to drop in to automation
write.

{GLOBAL DROP-OUT} Key
Causes all controls to drop out of automation record returning to
automation ‘ready’ status.

Note:

‘Film Mode’ allows the system to be set up so that {GLOBAL DROP-IN} and
{GLOBAL DROP-OUT} are operational on all controls except Faders, Cuts and
Pans (see section 7-7-9).

“UNDO” & “REDO” for Automation Data

{UNDO} Key
Causes the system to go back one mix pass at a time for each UNDO
through the currently unsaved mixes in memory, until the point of the last
SAVE MIX command point is reached.

{REDO} Key
Reverses the effect of UNDO commands one by one.

{UNDO ALL} Key
Reverts all the way back to the last SAVE MIX command point.

{REDO ALL} Key
Cancels the effect of the UNDO ALL key.

Ranges and Lists

Channels, Control Groups and the Main Fader can be specified in
command lines for certain functions:

Ranges are specified with ‘..’ as a separator.
1..108

= Channels 1-108

01..032

= Control Group Faders 1-32

00

= Main Fader

Individual items are separated by ‘.’
2 . 4 . 25

= Channels 2, 4, and 25