Sony OXF-R3 User Manual

Page 56

Advertising
background image

3-30

Chapter 3

Getting Started

Chapter 3 Getting Started

3-10 Basic Console Operations

3-10-12 To Set Up a De-Esser Using Dynamics Side-Chain EQ

1

Press {ACCESS} for the desired Channel.

2

At the Input Channel & Inserts panel, select
‘DYN’ in one of the eight windows. Do this using
the { + } and { – } buttons, and then press the large
{ IN } button.

3

At the Free Assign Area & Dynamics panel, select
SC EQ IN; its {ACCESS} button will light
automatically.

4

At the same panel, press the button adjacent to the
SIG EQ display and adjust the HF controls to
boost the frequency band to be attenuated.

5

Now de-select SIG EQ and select S-C EQ to
affect just the side-chain signal.

6

At the same panel, select COMPRESS { IN } . The
Compressor {ACCESS} will be selected
automatically, allowing the compressor to be set.

7

Select the Dynamics softkey to view compressor
parameters and transfer curve graph on the LCD
screen.

1

3

7

2

4

5

6

Advertising