6 the session management™ screen pages – Sony OXF-R3 User Manual

Page 322

Advertising
background image

7-62

Chapter 7

Session Management

Chapter 7 Session Management

7-6 The Session Management™ Screen Pages

STATUS column

This uses a pop-up to allow the selection of the status
of machines as follows:

• MASTER

Selects a machine as the Timecode Master. There
can be only one Timecode Master so selecting
MASTER (and the COMMIT) will take the
Timecode Master status away from any other
machine.

• SLAVE

Selects a machine as a Slave to the Timecode Master
machine. The remotes for this machine will follow
whatever the Master does but will not be operative
themselves.

• INDEP

Selects a machine to be Independent and fully
operative.

ABSOLUTE TIMECODE

The ABSOLUTE TIMECODE display indicates the
timecode for its machine.

SYNC column

If belonging to a Slave, the Timecode Display shows
00:00:00:00 when locked, or the difference between
itself and the Master whilst becoming synchronised. If
the system is unable to synchronise this machine with
the Master, the timecode difference will be displayed.

The Sync Flag, situated below the sync timecode
readout for each machine, displays the SYNC status
i.e. LOCKED, UNLOCKED.

OFFSET column

Click on the Timecode Display for a pop-up to allow
OFFSET adjustment.

Using the Numeric Key-pad to Enter Timecode

The entry format is exactly the same as that used for
PCM-3324/48 series remote control units:

1

= 00:00:01:- -

12

= 00:00:12:- -

1234

= 00:12:34:- -

12345

= 01:23:45:- -

123456

= 12:34:56:- -

12345621

= 12:34:56:21

12:34:56:21

= 12:34:56:21

12:34:56

= 12:34:56:- -

Timecode shortforms:

::

Separates hours/minutes

:

Separates minutes/seconds

.

Separates seconds/frame

12::

= 12:00:00:00 Specifies hours

34:

= 00:34:00:00 Specifies minutes

56

= 00:00:56:00 Specifies seconds

.21

= 00:00:00:21 Specifies frames

The Motion Status Flag, situated below the timecode
offset readouts, displays the motion status: PARKED,
PLAYING, WINDING, REWINDING etc.

SUBFRAME column

Click on for a pop-up to type in a Subframe offset
between 0 and 99 which can be negative or positive.
Prefix with ‘-’ for a negative number.