Chapter 3 _____________________________________________ Configuring Modules and Sensors
VAISALA______________________________________________________________________ 111
In order to have access to the sensor interface, the serial line parameters
have to be set to match those on the sensor. The easiest way to do this
is to create a setup with Lizard Setup Software. Select the correct
interface modules and parameters and run the setup.
Once the serial line parameters are correct, a pass-through access to the
connected sensors is allowed. You can open it from the QML logger
command shell by issuing the open command with the parameters
presented in
NOTE
When a separate service interface, usually RS-232, is available in the
sensor, it is recommended that you use it for the initial configuration.
The 2-wire RS-485 which operates in half duplex does not always
provide problem-free access to service connection. Also, note that
keystrokes are not echoed by the sensor.
Table 10
Parameters for the Open Command
Connector in Lizard
Parameter
Alias
COM0
COM0
COM0
COM1
COM1
COM1
DMX501 (MOD1/1)
DMX501_0
MOD1
DMX501 (MOD2/1)
DMX501_1
MOD2
DSI485A (MOD1/1)
DSI485_0
MOD1
DSI485A (MOD2/1)
DSI485_1
MOD2
DSI486 (MOD1/1)
DSI485_0_0
MOD1_2
DSI486 (MOD1/2)
DSI486_0_1
1
1. With the dual RS-485 module, the RS-232 connection is possible only to
the channel B on the module, and thus the last number is 1.
MOD1_1
DSI486 (MOD2/1)
DSI486_1_0
MOD2_2
DSI486 (MOD2/2)
DSI486_1_1
1
MOD2_1
DSI486SDI (MOD1/3)
DSI486SDI_0
MOD1_3
DSI486SDI (MOD2/3)
DSI486SDI_1
MOD2_3
DSU232 (MOD1/1)
DSU232_0_0
2
2. With the RS-232 and dual RS-485 modules, the number between the
underline characters stands for the module place, that is, MOD1 or MOD2,
and the last number for the channel on that particular module.
MOD1_1
DSU232 (MOD1/2)
DSU232_0_1
MOD1_2
DSU232 (MOD2/1)
DSU232_1_0
MOD2_1
DSU232 (MOD2/2)
DSU232_1_1
MOD2_2
DSU232SDI (MOD1/3)
DSU232SDI_0
MOD1_3
DSU232SDI (MOD2/3)
DSU232SDI_1
MOD2_3