Report Setup for the Secondary Transmission

You do not have to set up any log group for the secondary
transmissions, as only the latest data is included in the random and
emergency reports. Instead, set up a report including the latest data as
follows:

1.

In the Reports view, create a new StringForm report.

2.

In the first cell, add the text SECONDARY, in order to define that
the report will be transmitted on the secondary channel. Add the
text in the Text field under the Cell properties tab.

3.

Starting from the second cell, add all desired variables to the report.

4.

To include the transmission count in the report, add the variable
Counter of Report to the report. The counter starts from zero and
it will increase by one each time a new report is transmitted. The
counter will not increase when repeating the same transmission.

5.

All data included in the secondary transmissions must be
compressed using the pseudo-binary format. Under the Report
properties
tab in the Report formatting field, select Pseudo-
Binary
. Configure the pseudo-binary compression of each variable
as described in section

Pseudo-Binary Report Format on page 167

.

NOTE

In the next step, enter also the trailing comma (,) when entering text
SECONDARY, in the Text field.

NOTE

The Report formatting field is visible only on the Advanced user
level.