Leaf wetness sensor, Figure 40, Lizard waterlevel window – Vaisala Hydromet Data Collection Platform User Manual
Page 85

Chapter 3 _____________________________________________ Configuring Modules and Sensors
VAISALA_______________________________________________________________________ 83
Setting Current Water Level for Multiple Shaft
Encoders
If you have more than one absolute shaft encoder in your system setup,
you must define the device number when entering the waterlevel
command. To see which command is associated with a certain device,
click the waterlevel commands button in the Communications frame
of the Measurements view in Lizard, as seen in
.
A window opens, displaying the QSE devices and the commands
associated with them, see
0711-146
Figure 40
Lizard Waterlevel Window
For example, to set the current waterlevel to 6.120 meters for the
QSE104_2 sensor, give the following terminal command:
/> waterlevel_2 6.120
water level = 6.1200 m
Leaf Wetness Sensor
The leaf wetness sensor is configured in the Equipment view in
MAWS Lizard. To configure the sensor, proceed as follows:
1.
Open an existing setup in the Setup view or create a new one.
2.
Proceed to the Equipment view.
3.
Select the QLW102 sensor from the Available list and click Add
to insert the sensor into the setup.
4.
If the connector is used, MAWS Lizard prompts 'Selected HW
resource is already in use. Are you sure you want to make this
connection'.
a.
Select No.
b.
Double-click the text <None> in the Connector column.
c.
Select an available connector.