Transmitter Configuration
The configuration parameters of the transmitter are set through the
service terminal with the following command:
CFG <name> <parameter> <value>
A response to the command can be received by giving the command
LASTVAL <name> service. The response can be either
ID set
,
ID
set failed
,
Clock set
, or
Clock set failed
.
After power-up, before any transmissions can be made, the clock must
be set if the transmitter does not have an embedded GPS. The
transmitter ID stored to EEPROM is used after the power-up. If no ID
has been stored, one must be set before any transmissions can be made.
where
CFG
=
Configuration command
name
=
Transmitter name as given in Lizard; for example,
GOES_1
parameter =
Any of the items in the Parameter column in
value
Any of the items in the Value column in
Table 18
Transmitter Configuration Parameters
Parameter
Value
Description
setid
8-character hexadecimal string,
for example, "010012D4"
Sets the ID of the
transmitter without storing
it to EEPROM
setid_eeprom 8-character hexadecimal string,
for example, "010012D4"
Sets the ID of the
transmitter and stores it to
EEPROM
setclock
String including Year, Month,
Day, Hours, minutes, and
seconds in the format
YYMMDDhhmmss
Sets the transmitter clock
(only used for transmitters
without embedded GPS)