Table 69 – Vaisala Hydromet Data Collection Platform User Manual
Page 322

User's Guide ______________________________________________________________________
320 _________________________________________________________________ M210933EN-C
The IP services, FTP server, and service terminal, reside in the local
data acquisition system. The benefits of using a serial line IP connection
in this kind of configuration are:
-
Standard file transfer method
-
Possibility to establish multiple simultaneous links over one serial
line
1.
Configure the PPP connection in the local data acquisition system
with the parameters presented in
. Further
information on creating dial-up/in interfaces in Windows PCs and
configuring their parameters can be found in Windows online help.
2.
Add and configure the physical communication devices in the
setup.
a.
In the Optional hardware view, add module DSU232 to an
available module place.
b.
In the Devices view, add the device WinNullModem-IP.
NOTE
Half-duplex links, such as two-wire RS-485, are not suitable as PPP
carriers with the QML logger. Whenever possible, using Ethernet
should be preferred.
Table 69
PPP Connection Parameters in Remote Data
Acquisition System
Parameter
Description
Link parameters
9600 bps, 8 data bits, 1 stop bit, no
parity, no flow control
Local IP address
10.0.0.1
Remote IP address
10.0.0.2
Authentication method
PAP
PPP dial-in user name
pppuser
PPP dial-in password
userppp
PPP dial-out user name
qmluser
PPP dial-out password
userqml
NOTE
Using link speeds over 9600 bps is not recommended.
NOTE
If the local data acquisition system is running an operating system
other than Windows, use the device NullModem-IP instead.