Table 24, Minimum changes to hal2 parameters – Vaisala Hydromet Data Collection Platform User Manual

Page 199

Advertising
background image

Chapter 4 ________________________________________________ Configuring Telemetry Options

VAISALA______________________________________________________________________ 197

7.

Modify the HAL2 configuration by pressing F. The following
menu is displayed:

8.

To change a value for a menu item, first press the corresponding
letter key and then press ENTER to change the values. Refer to
HAL2 documentation for the correct values. At minimum, the
following menu items need to be modified:

9.

Save your configuration by pressing V.

A) EMIS. COURANTE : 1
B) TR FIXE : 0
C) ADRESSE 28 : 0
D) MESSAGE INTERNE: 0
E) HEADER PRESENT : 0
F) NBR OCTETS EXT : 32
G) ID : 00000001
H) FREQUENCE : 401647000
) PUISSANCE : 1W
J) HEADER : 25
K) RESOL PUISSANCE: 0
L) RESOL ALIM : 10
M) RESOL TEMP. : 0
N) RESOL COMPTEUR : 0
O) TOR1 : 0
P) TOR2 : 0
Q) RESOL AN1 : 0
R) RESOL AN2 : 0

S

) RESOL AN3 : 0

T) RESOL AN4 : 0
U) MSG:
FFFFFFFFFFFFFFFFFFF001FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
FFFFFFFFC00
V) MEMORISE

Table 24

Minimum Changes to HAL2 Parameters

Parameter

Value

C) ADDRESS

Use a 25-bit or 28-bit address

D) MEDSSAGE INTERNE

To enable external messages to be sent from
MAWS, set to 0.

G) ID

Set to an appropriate value.

H) FREQUENCE

Set to an appropriate value.

I) PUISSANCE

Set to an appropriate value (transmission
power)

Advertising