Table 24, Minimum changes to hal2 parameters – Vaisala Hydromet Data Collection Platform User Manual
Page 199

Chapter 4 ________________________________________________ Configuring Telemetry Options
VAISALA______________________________________________________________________ 197
7.
Modify the HAL2 configuration by pressing F. The following
menu is displayed:
8.
To change a value for a menu item, first press the corresponding
letter key and then press ENTER to change the values. Refer to
HAL2 documentation for the correct values. At minimum, the
following menu items need to be modified:
9.
Save your configuration by pressing V.
A) EMIS. COURANTE : 1
B) TR FIXE : 0
C) ADRESSE 28 : 0
D) MESSAGE INTERNE: 0
E) HEADER PRESENT : 0
F) NBR OCTETS EXT : 32
G) ID : 00000001
H) FREQUENCE : 401647000
) PUISSANCE : 1W
J) HEADER : 25
K) RESOL PUISSANCE: 0
L) RESOL ALIM : 10
M) RESOL TEMP. : 0
N) RESOL COMPTEUR : 0
O) TOR1 : 0
P) TOR2 : 0
Q) RESOL AN1 : 0
R) RESOL AN2 : 0
S
) RESOL AN3 : 0
T) RESOL AN4 : 0
U) MSG:
FFFFFFFFFFFFFFFFFFF001FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
FFFFFFFFC00
V) MEMORISE
Table 24
Minimum Changes to HAL2 Parameters
Parameter
Value
C) ADDRESS
Use a 25-bit or 28-bit address
D) MEDSSAGE INTERNE
To enable external messages to be sent from
MAWS, set to 0.
G) ID
Set to an appropriate value.
H) FREQUENCE
Set to an appropriate value.
I) PUISSANCE
Set to an appropriate value (transmission
power)