Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry

VAISALA______________________________________________________________________ 307

6.

In the IP Services view, add and configure an SMTP client for
alarm message transmittal.

-

Add an SMTP client.

-

Configure the following items for the SMTP client:

-

Source domain: Use an existing one, for example, a
company domain. SMTP servers often reject messages
from unknown domains.

-

Destination server: This server must be available on the
GSM operator’s network. For more information, see
connection settings often provided on an operator’s web
pages.

-

Primary interface: netif0, for instance, using the GSM
modem.

7.

In the Reports view, create a report to be sent to the FTP server.

8.

Create an alarm report to be sent as an e-mail alert.

9.

In the Communications view, shown in

Figure 147 on page 307

,

link the report to the previously created FTP client for
transmission, and configure the transmission parameters.

0710-115

Figure 147

Configuring Report Transmission for FTP
Client