Transmission control for primary transmissions, Table 19, Transmission control for primary – Vaisala Hydromet Data Collection Platform User Manual

Page 177

Advertising
background image

Chapter 4 ________________________________________________ Configuring Telemetry Options

VAISALA______________________________________________________________________ 175

Examples:

The transmitter ID is set to "010012D4" and stored to EEPROM as
follows:

open

/ > CFG GOES_1 setid_eeprom "010012D4"

/ > LASTVAL GOES_1 service

Status:1 Value: ID set

/ >

The transmitter clock is set to 15.11.2005 13:17:00 as follows:

/ > CFG GOES_1 setclock "051115131700" / >

/ > LASTVAL GOES_1 service

Status:1 Value: Clock set

/ >

Transmission Control for Primary Transmissions

The parameters that are needed for controlling the transmissions are set
with the following command:

spset <parameter> <value>

You must set the parameters listed in

Table 19 on page 175

.

Table 19

Transmission Control Parameters for Primary
Transmissions

Parameter

Value

Description

goes_txtime

0...86400 seconds Time of the first transmission on

each day, given in seconds since
midnight

goes_window

0...n seconds

Length of the transmission window in
seconds

goes_interval

0...n seconds

Interval between transmissions in
seconds

goes_channel

0...266

Transmission channel number