Pstn-dependent configurations, Transmission mode, Figure 70 – Vaisala Hydromet Data Collection Platform User Manual

Page 148: Pstn transmission configuration options

Advertising
background image

User's Guide ______________________________________________________________________

146 _________________________________________________________________ M210933EN-C

It is recommended that you use the Station setting parameter because
it provides the possibility to change the destination without changing
the setup. The Station setting parameters can be set using either of the
following:

1.

With the terminal software Station settings window.

2.

With the spset <param> <value> command in the service
connection.

PSTN-Dependent Configurations

The modem control can only use data calls for transferring the reports
over the public telephone network (PSTN).

0711-159

Figure 70

PSTN Transmission Configuration Options

Transmission Mode

The Transmission mode parameter allows selection between the two
modes:

1.

Data call: The report is automatically sent to the destination by
making a call. The report can also be polled, if the Poll command
is defined.

2.

Polled only: The report is only sent when polled by the remote
system.

NOTE

Always use quotation marks around the parameter value for
destination. For example: spset sms_to "0401234567"

Advertising