Formatting report, Linking report to communication port, Table 23 – Vaisala Hydromet Data Collection Platform User Manual

Page 190: Default transmit control strings for inmarsat-c

Advertising
background image

User's Guide ______________________________________________________________________

188 _________________________________________________________________ M210933EN-C

2.

Under Options, select Command parser for handling remote
commands. When you select Extparser, the remote commands are
processed as described in section

Remote Maintenance Commands

on page 199

.

3.

Under Transmit control, you need to enter a string that depends
on the service provider and destination network. The default
parameters are listed in

Table 23 on page 188

.

Formatting Report

In the Reports view, the reports that are sent to Inmarsat must be
formulated according to the following examples. The report structure
for the Internet e-mail is as follows:

TO:[email protected]<CR><LF>
CC:[email protected]<CR><LF>
SUBJECT:Your mail subject<CR><LF>
<CR><LF>
message body

The report structure for fax (phone number 3589123456) is as follows:

3589123456+<CR><LF>
<CR><LF>
message body

Linking Report to Communication
Port

In the Reports view, link the report to the communication port used by
the Inmarsat transceiver.

Table 23 Default Transmit Control Strings for Inmarsat-C

String

Description

c 104

Destination ground LES/provider EIK/Sonera

s 0

Delivery service, store-and-forward

t 6

Destination Internet

e 28

Destination extension e-mail

l 0

Defines standard 8 bit alphabet