Figure 138 sms handler interfaces, Table 58, Configuration parameters for sms handler – Vaisala Hydromet Data Collection Platform User Manual
Page 293

Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry
VAISALA______________________________________________________________________ 291
When using the SMS Handler for interface state management without
automatic connection to remote server:
1.
In Lizard, select the name(s) of the managed interface(s) in the lists
available in the Controlled network interfaces window.
0811-022
Figure 138
SMS Handler Interfaces
2.
When you need to connect an interface to network, send an SMS
with the following content:
connect intfX
where X is the number of the interface in the Controlled network
interfaces window. For example, to connect to interface number 2,
send:
connect intf2
Table 58
Configuration Parameters for SMS Handler
Parameter
User
Note
Controlled
network
interfaces
Lists names of the controlled
network interfaces, if any. At
maximum, there can be three
network interfaces controlled
by the same SMS Handler.
Communication
device
Modem to listen for incoming
SMS.
Info printouts to
COM0
Produces additional
informative output to COM0.