Troubleshooting GOES
Transmission

If a transmission fails, a

Transmission failed

warning will be

generated. An error code showing the reason for the failure can be read
by giving the following command:

LASTVAL <name> service

Example:

LASTVAL GOES_1 service

Below is a list of the possible error codes:

-

0x04: Invalid transmission start time

-

0x05: Transmission overlaps another transmission

-

0x06: Invalid transmission channel

-

0x0A: Transmitter clock not set

If any of required static parameters (parameters set with the spset
command) are invalid or missing, no transmission will be made. A
warning will be generated indicating which parameter is missing or
invalid.