Vaisala Hydromet Data Collection Platform User Manual
Page 48

User's Guide ______________________________________________________________________
46 __________________________________________________________________ M210933EN-C
An example output from the QML logger after selecting a setup file to
be executed from the CF card is as follows:
/ W> dir /Ext/TEST
.rwxd 13:11:40 21.03.2005 0
..rwxd 13:11:40 21.03.2005 0
setup501.adcrw-- 12:26:28 21.03.2005 1776
Files shown: 3 Bytes used: 1776
/ W> reset 0 /Ext/TEST/setup501.adc
Resetting device in 0 seconds
COM0: QML201 Startup - Warm Boot
Serial # : Z402074
Hardware : Rev B-001
Software : 5.01 Checksum : 00000000
Boot sw version : 4.07
System RAM : 2048kB
Free memory : 1768kB
Internal temp. : 23.15'C
Active errors : NO
Active warnings : NO
Piggyback - 0 : DSU232 rev: B serial no: 008232
Piggyback - 1 : DSU232 rev: B serial no: 003523
NEW flash checksum (02400000 to 025FFFFF) is BBCC1130
Found setup /Ext/TEST/setup501.adc
Starting to execute setup
Setup running ok
NOTE
You can also copy a setup file to the CF card and take it into use by
giving only one command. When entering the following command, the
QML logger will overwrite the original setup file in the /Cfg directory.
The new setup will thus be available after each restart.
reset [delay] /Ext/<setup file> copy
For example, to copy and to take into use the setup501.adc setup file,
give the following command:
reset 0 /Ext/test/setup501.adc copy