Commands for terminal connection, Commands for parameter sets, Table 60 – Vaisala Hydromet Data Collection Platform User Manual
Page 295: Commands for parameter

Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry
VAISALA______________________________________________________________________ 293
Commands for Terminal Connection
This section presents the QML logger shell commands for configuring
parameter sets and TCP/IP-based connections.
Commands for Parameter Sets
The commands available for manipulating parameter sets are presented
in
.
Examples of paramset command output:
/ > paramset
GSM_Siemens_1
pppclients
netif0
netif1
VCOM0
Table 60
Commands for Parameter Sets
Command
Use
paramset
Lists all parameter sets
paramset <set>
Shows values of all parameters in
the given set
paramset <set> <parameter>
Shows value of single parameter is
the given set
paramset <set> <parameter>
<value>
Creates or sets value for parameter
in the given set.
paramsetclear <set>
Removes a complete parameter set
paramsetclear <set> <parameter>
Removes a single parameter from
the given set
NOTE
When setting station-specific IP addresses, phone numbers, or PIN
codes using the QML service terminal, double quotation marks must
be used around the value. For example: paramset eth1 address
"10.0.0.1"