Table 76, Jumper settings for channel b in the rs-232 mode – Vaisala Hydromet Data Collection Platform User Manual
Page 344
Advertising

User's Guide ______________________________________________________________________
342 _________________________________________________________________ M210933EN-C
0201-049
Figure 176
Dual RS-485 Module Default Jumper Locations
1006-102
Figure 177
Dual RS-485 Wiring Diagram for RS-485 and RS-232
provides a schematic wiring diagram for the
combination of the RS-485 and RS-232 connection. The correct jumper
settings for the channel B are listed in
.
Table 76
Jumper Settings for Channel B in the RS-232 Mode
Jumper
Connected
Pins
Function
X3
2-3
Sets the RS-232 mode active for the channel B.
X6
1-4
2-5
X5
None
The line terminating resistor is not in use at all.