Vaisala Hydromet Data Collection Platform User Manual
Page 158

User's Guide ______________________________________________________________________
156 _________________________________________________________________ M210933EN-C
The interface allows processing of remote maintenance commands as
listed in
. To enable the use of remote commands,
proceed as follows:
1.
Select the Process inbound messages option.
2.
Under Command processing, select Extparser in the Command
parser field.
3.
If you want to receive responses to commands, select also the Send
responses to commands option.
Timeout
2000 ... 30000 ms
Timeout for the communication
between QML logger and the
communicator
Options
GPS receiver
Communicator is equipped with GPS
Clear queue on
startup
Clears transmission queue upon
startup
Clear queue if full
Clears transmission queue if it
becomes full
Priority mask lo
Priority mask hi
Priority mask for communications (do
not modify)
Process inbound
messages
QML logger polls and processes
inbound messages as remote
commands
Send responses to
commands
QML logger sends responses to the
inbound commands
Extra op. info to
COM0
Sends extra operation information to
COM0 for troubleshooting
Time
adjustment
tolerance
-1 = disable
1 ... 3600 s
When the current system time differs
from the GPS time more than the
tolerance set with this parameter, the
system time is adjusted to match the
GPS time
Parser
component
2
Empty, <None>, or
Extparser
Parser used to process remote
commands
1. The maximum length of the user data is 229 characters for the globalgram
message type, while with enhanced globalgram recipient the subject and
message body can have 225 characters in total.
2. Visible only in advanced Lizard operation mode.
Table 14
ORBCOMM Communicator Parameters in Lizard
(Continued)
Parameter
Value
Description