Table 53, Parameters for modem command exchange – Vaisala Hydromet Data Collection Platform User Manual
Page 284

User's Guide ______________________________________________________________________
282 _________________________________________________________________ M210933EN-C
3.
Define the command exchanges associated with the different
states. The parameters for a command exchange are presented in
4.
As needed, adjust the order of execution as described in section
Generic IP Modem Configuration on page 275
Table 53
Parameters for Modem Command Exchange
Parameter
Use
Type
Selection if executed when entering or exiting
the state.
State name
Name of the state in which the command
exchange is executed.
Command to send
One of the defined commands to send.
Expected response
Name(s) of expected response(s). The list may
be empty, that is, no response, or it may
contain multiple responses separated by
commas. Do not enter the modem response
string(s) here, but use the response names
defined in the previous step. Make sure that
you type the name(s) correctly, including
upper/lower case. List also the error
responses; otherwise, they will exit only
through a timeout.
Conditional response
Name of the previous response for conditional
execution, that is, this command exchange will
be executed only if the previously received
response matches the given response. For
example, the PIN code setting for GSM
modem will be executed only if the previous
response indicates that it is needed. For an
example, see the command exchange
AT_pinset for device Siemens GPRS-IP in
Lizard Setup Software.
Timeout
Timeout for the command in milliseconds.
Retries
Number of retries in case of failure.
Options
Negate conditional = Execute only if the
previous response was not the given one;
Ignore error = ignore error responses.