Table 54, Parameters for asynchronous response – Vaisala Hydromet Data Collection Platform User Manual
Page 285

Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry
VAISALA______________________________________________________________________ 283
0710-073
Figure 131
Example Command Exchange Configuration
5.
Define asynchronous responses. Parameters for an asynchronous
response are presented in
Typically, the only processed asynchronous response is the
indicator for an incoming call, that is, it is associated with the
RING response.
An example of generic modem asynchronous response
configuration is presented in
.
0710-074
Figure 132
Example Asynchronous Response Configuration
6.
Once the configuration is completed, you can test the operation:
a.
Ensure that the option Debug output is selected and observe
the debug output from the QML logger service port COM0.
b.
Lizard Setup Software makes only basic checking of the
modem parameters. Many configuration problems are
reported as warnings or errors during and after the QML
logger startup. Use the QML logger shell commands
warnings and errors to check for problems.
Table 54
Parameters for Asynchronous Response
Parameter
Use
State name
State where processed
Modem response
Name of the modem response