Cellular modems, Table 102, Com server unit environmental specifications – Vaisala Hydromet Data Collection Platform User Manual

Page 377: Table 103, Gsm terminal tc35i specifications

Advertising
background image

Appendix A _____________________________________ Configuration Information for Legacy Items

VAISALA______________________________________________________________________ 375

Cellular Modems

Table 102

COM Server Unit Environmental Specifications

Property

Description/Value

Operating temperature

-40 °C ... +55 °C (-40 ... +131 °F)

Storage temperature

-60 °C ... +75 °C (-76 ... +167 °F)

Humidity

5 to 95 % RH, non-condensing

EMC

EN 55022

Immunity
ESD

EN 61000-4-2, contact dis. 4kV, air dis. 8kV

RF field

EN 61000-4-3

Fast transient bursts (EFT) EN 61000-4-4
Transient surges

EN 61000-4-5

Conducted RF

EN 61000-4-6

Vibration

IEC 68-2-64 Fh, 10 ... 500 Hz, up to 2.0 G

Free fall

IEC 68-2-32 Ed, fall height 1000 mm

Cold

IEC 68-2-1, -40 °C 16 hours

Heat

IEC 68-2-2, +55 °C 16 hours

Slow change of
temperature, 1°C/min

IEC 68-2-14, -40 °C ... +55 °C, two cycles

Table 103

GSM Terminal TC35i Specifications

Property

Description/Value

Sensitivity

-104 dBm

Dual Band

EGSM900/GSM1800

Data transmission

CSD up to 14.4.kbps
USSD
Non transparent mode
V.110
7E1-character framing

SMS

Included

Tx power

2 W (class 4)
1 W (class 1)

Supply voltage

8 ... 30 V

Power consumption
Transmit mode

300 mA (average)

Idle mode

10 mA

Sleep

3 mA

Power down

0.1 mA

Temperature range

-20 ... +55 °C

Weight

130 g (4.6 oz.)

Advertising