Configuring communication port of nokeval 7470, Figure 18 – Vaisala Hydromet Data Collection Platform User Manual
Page 56

User's Guide ______________________________________________________________________
54 __________________________________________________________________ M210933EN-C
Configuring Communication Port of Nokeval 7470
One or several Nokeval devices are connected to the QML logger
through an RS-485 communication port. The device can be connected
to the following RS-485 ports:
-
Integrated RS-485 port (COM1)
-
Isolated RS-485 port (2-wire or 4-wire connection)
In the Optional hardware view of Lizard Setup Software, configure
the selected RS-485 port as follows:
1.
In the Line parameters frame, leave the default values (9600, 8, 1,
none), unless the Nokeval device is to be otherwise configured. See
.
2.
In the Wiring options frame, select the Two wire connection type
from the list (isolated DSI485A only).
3.
Leave all options unselected in the Handshake options frame.
0711-115
Figure 18
Optional Hardware View: Configuring
Communication Port for Nokeval 7470 (1/2)