Configuring orbcomm communicator, Hardware setup, Formatting reports – Vaisala Hydromet Data Collection Platform User Manual

Page 155: Hardware setup formatting reports

Advertising
background image

Chapter 4 ________________________________________________ Configuring Telemetry Options

VAISALA______________________________________________________________________ 153

Configuring ORBCOMM
Communicator

Hardware Setup

The ORBCOMM communicator is connected to the QML logger using
the RS-232 interface, through the RS-232 communication module. You
should add the communication module to the setup and set the
parameters in the Optional hardware view of Lizard Setup Software.
Under Line parameters, enter the following configuration parameters
for the module:

-

Speed: 4800 bps

-

Data bits: 8

-

Stop bit: 1

-

Parity: None

In the Devices view, add the communicator to the setup. Under I/O
Connections
, connect the transceiver to the previously configured
communication module.

Formatting Reports

Configure the reports to be sent to ORBCOMM interface using the
StringForm report template in the Reports view. The report must be
formatted as follows:

<address>,<subject>,<message>

where
address

=

Destination e-mail address, or the preset speed
dial number for communicator. Eight preset speed
dial addresses in total can be defined when the
communicator is commissioned for data
transactions. Using these addresses reduces the
amount of data per transmission and allows the
use of the Globalgram mode

subject

=

E-mail message subject, for example, station
name

message

=

Report contents

Advertising