Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry
VAISALA______________________________________________________________________ 331
3.
Enter the following parameter values (only the parameters relevant
for SMS configuration are listed):
4.
Click Save to close the settings.
It is also possible to use an external program to execute the sending. In
this case, select Use external command and enter startup command
and parameters for launching the external program to Program
command line. In this case, neither the modem settings nor Wake-up
message are used.
Table 72
SMS Configuration Parameters
Parameter
Value
Note
Type
Server socket with
SMS.
Port
Port where the logger is
configured to connect
to.
For more information,
see section
GSM Modem
COM port
PC COM port where the
GSM modem is
connected to.
GSM Modem baud rate Baud rate for the GSM
modem.
GSM Modem flow
control
Flow control mode for
the GSM modem.
Telephone number
Telephone number of
the logger’s GSM
modem.
Wake-up message
open <connX>, where
<connX> refers to the
logger SMS handler
configuration
For more information,
see section
Optional initialization
commands
Additional initialization
commands for the
modem.
For example,
AT+CPIN="XXXX"
AT+CSCA="<sms
central number>"
NOTE
Connecting to logger with this method can involve significant delays,
depending on how fast the SMS gets through and the logger manages
to establish a GSM connection for IP.