Cygnus 2 Operating Manual

CONTROL DELAY TIME . . . . . . . . . 00:00 to 99:59

This is the time interval for the Cygnus 2 to be held in the Control Delay state.
The parameter is displayed only if the Delay Option chosen is Control or Both.
The default value is 00:00.

SHUTTER DELAY ACCURACY . . . 1 to 99%

Specifies how close the rate value must be to the setpoint value for 5 seconds
before opening the Source shutter.The parameter is displayed only if the Delay
Option chosen is Shutter or Both. The default value is 5.

5.1.6 Post Deposit Parameters

Feed Ramp State

The next three parameters define a feed ramp provided to maintain power levels
during a wire feed. After reaching Final Thickness, the Cygnus 2 will enter the Feed
Ramp state for the specified time. Control voltage is ramped from the power level
at the end of the DEPOSIT state to the Feed Power level. Feed Power is held
constant until the end of Feed Time. At the end of Feed Time, the Cygnus 2 will
proceed to the Idle ramp state. Source and Sensor shutter are inactive.

FEED POWER . . . . . . . . . . . . . . . . . 0.0 to 99.99%

This is one of three parameters used to affect a Feed Ramp. This value
establishes the control voltage power level at which the Source is maintained
during wire feed. The default value is 0. If set to a value greater than Maximum
Power, Maximum Power has priority.

FEED RAMP TIME. . . . . . . . . . . . . . 00:00 to 99:59 min:s

This is the time interval for the Source power to ramp linearly from the power
level at the end of Deposit to Feed Power level. The Feed state is active during
Feed Ramp Time. The default value is 00:00.

FEED TIME . . . . . . . . . . . . . . . . . . . 00:00 to 99:59 min:s

This is the time interval for which the Source power is maintained at Feed
Power. The Feed state is active during Feed Time. The default value is 00:00.

Idle Ramp State

The next two parameters define an idle ramp provided to establish the Source
power level after the Deposit or Feed state. Control voltage is ramped from the
power level at the end of the Deposit state (or Feed Power, if one is set) to the Idle
Power level. The control voltage is maintained at the Idle Power level until the
Cygnus 2 enters the STOP state or until the next Material, using the specified
Source, is started, or the turret source is rotated.